Home > Products Information > New product > SLIDE GUIDE [ SGL-HTEX Type ]
BLOCK TYPES and STRACTURE | SIZE and SPECIFICATION | ACCURACY | PRE-LOAD
BLOCK TYPES and STRACTURE
- SGL 6-Hole type guide.
- Better hold for better precision.
 (890KB)
SIZE and SPECIFICATION
[SGL-HTEX Type]
Click to view
ACCURACY
Three accuracy grades are available: normal-grade(no suffix), high-grade(H), and precision-grade(P).
Table 1 Accuracy
| part number |
SGW15,20 |
SGW25,30,35 |
SGW45 |
| accuracy grade |
normal |
high |
precision |
normal |
high |
precision |
normal |
high |
precision |
| accuracy symbol |
none |
H |
P |
none |
H |
P |
none |
H |
P |
| allowable dimensional tolerance for height H |
±0.1 |
±0.03 |
-0.03 ~ 0 |
±0.1 |
±0.04 |
-0.04 ~ 0 |
±0.1 |
±0.05 |
-0.05 ~ 0 |
| paired difference for height H |
0.02 |
0.01 |
0.006 |
0.02 |
0.015 |
0.007 |
0.03 |
0.015 |
0.007 |
| allowable dimensional tolerance for width W |
±0.1 |
±0.03 |
-0.03 ~ 0 |
±0.1 |
±0.04 |
-0.04 ~ 0 |
±0.1 |
±0.05 |
-0.05 ~ 0 |
| paired difference for width W |
0.02 |
0.01 |
0.006 |
0.03 |
0.015 |
0.007 |
0.03 |
0.02 |
0.01 |
Running parallelism of surface C to surface A
Running parallelism of surface D to surface B |
refer to Figure 1 |
*unit/mm
PRE-LOAD
SGL slide guides are available with a standard pre-load (no suffix), light pre-load(T1), and medium pre-load(T2).
Table 2 Pre-load Symbol and Radial Clearance
| pre-load category |
standard |
light |
medium |
| pre-load symbol |
none |
T1 |
T2 |
| SGL15 |
-4 ~ +2 |
-12 ~ -4 |
NA |
| SGL20 |
-5 ~ +2 |
-14 ~ -5 |
-23 ~ -14 |
| SGL25 |
-6 ~ +3 |
-16 ~ -6 |
-26 ~ -16 |
| SGL30 |
-7 ~ +4 |
-19 ~ -7 |
-31 ~ -19 |
| SGL35 |
-8 ~ +4 |
-22 ~ -8 |
-35 ~ -22 |
| SGL45 |
-10 ~ +5 |
-25 ~ -10 |
-40 ~ -25 |
*unit/μm
Table 3 Operationg Condition and Pre-Load
| category |
symbol |
operating condition |
| standard |
none |
Minute vibration is applied.
Precision motion is required.
Moment in a given direction is applied. |
| light |
T1 |
Light vibration is applied.
Light moment is applied.
Moment is applied. |
| medium |
T2 |
Shock/vibration is applied.
Over-hang load is applied.
Torsional load is applied. |
 (890KB)
|
| When choosing linear system products, it is necessary to calculate elements such as load-bearing and accuracy, taking into consideration the type of machinery and environment in which the system will be used. Please refer to the Engineering Information page regarding technical calculations. |
|
|
>> Go to Engineering Information |
|
|
 |
|
> Back to Products Information |
|
|
|
|
|
|